AUTOOL BT-460 Battery Tester Lead-acid AGM GEL Battery Cell Analyzer 4‘’ TFT Colorful Display Auto Battery Testers Car Battery Analyzer Suppor 12V Vehicles & 24V Heavy Duty Trucks

  • ...healthy status to calculate the actual cold cranking capability of the battery and the aging extent, which provide reliable analysis evidence for the test and maintenance of the battery. It notifies the user to replace battery in advance when the battery getting aged..
  • Cranking test is mainly to test and analyze the starting motor. Through testing the actual required cranking current and cranking voltage of the starting motor, it can find out whether the starting motor works fine. There are several reasons why the starting motor is abnormal: lubricating system fault causing the starting loaded torque increasing or rotor friction of the starting motor causing the increasing friction of the starting motor itself..
  • Charging test is to check and analyze the charging system, including generator, rectifier, rectifier diode, etc. , thus to find out whether the output voltage of the generator is normal, the rectifier diode works fine and the charging current is normal. Suppose one of the above mentioned parts is not in normal situation, it will lead to over charge or incomplete charge of the battery, thus the battery will be quickly damaged and also greatly shorten the using life of other loaded electrical apply.
Check Stock

Atlas ESR70

  • Suitable for any capacitor type between 1uF and 22000uF including motor capacitors, smoothing capacitors, electrolytics, polypropylenes, in fact any dielectric type.
  • New enhanced dynamic range of 0.00 to 40.0 ohms.
Check Stock

PowerWell 45+7.5 uf MFD 370 or 440 Volt Dual Run Round Capacitor PW-CAP-45/7.5/440R Condenser Straight Cool/Heat Pump Air Conditioner

  • 45+7.5 MFD 440 VAC Capacitor. Replaces BOTH 370 & 440 VAC capacitors.
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • Can size measures 2-3/8" diameter x 3.94" tall..
  • Operating temperature range -40 C. to +70 C/ -40F to 158F.
Check Stock

Bryant P291-0753 • 7.5 uF MFD x 370 VAC Genteq Replacement Capacitor Oval # C307L / 27L566

  • 7.5uf ( 7.5MFD ) 370 Volt or 440 Volt Capacitor. Replaces BOTH 370VAC & 440VAC capacitors.
  • OVAL motor run capacitor. Can size measures 2" Wide , 3" Tall and 1.25 " thick. Operating temperature range -40 C. to +70 C/ -40F to 158F.
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • GUARANTEED TO LAST 5 YEARS 100% SATISFACTION GUARANTEE .We are extremely passionate about our products and are fanatical about quality control in our....
  • Replacement for: 1499-5461 , 27L566 , 27L566S , 97F9001 , Z97F9001 , 97F9001BX , 27L566BZ3 , TOCF7.5 , CPT-00120 , TP-CAP-7.5/440.
Check Stock

New Titan PRO TRCFD355 Capacitor

  • 35/5 uf or MFD micro farad 440 Volt Dual Run Round AC Capacitor . Replaces BOTH 370 & 440 VAC capacitors.
  • Can size measures 2" diameter x 4.75" tall..
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • Operating temperature range -40 C. to +70 C/ -40F to 158F.
  • Replacement for 97F9834 , Z97F9834 , HC98JA036 , P291-3553R , HC98CA036 , HV98CA035 , 97F9834, R100335-05, 89M73, HC98JA036D , TT-CAP-35/5/440R,....
Check Stock

BlueNatHxRPR Washer Start Capacitor 189-227 MFD uF 125V AC Compatible for Whirlpool Kenmore

  • Production Name: Washer Start Capacitor, Volume:189 - 227 MFD, Withstand Voltage: 125V AC,Shape: Round, Terminal Size:1/4in Standard Terminal(6.35x0.8mm).
  • Compatible and directly replace Whirlpool and Kenmore 8572717,482156,357021,3949169,661606,W10244889.
  • Widely used for laundry appliance as motor start capacitor,also used for small single phase motor such as washer motor, water pump and other home appliances motor.
  • Built to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • Most common universal US style capacitor, PCB free inside, 1 year warranty.
Check Stock

5 MFD Capacitor 370 or 440 VAC 5uf Oval Run Capacitor for Fan Motor Blower Condenser in Air Handler Straight Cool or Heat Pump Air Conditioner and Pool Pumps by The HVAC Genius

  • 5uf / 5MFD 370 Volt or 440 Volt Capacitor. Replaces BOTH 370VAC & 440VAC capacitors.
  • OVAL motor run capacitor. Can size measures 2" Wide , 2.5" Tall and 1.25 " thick. Operating temperature range -40 C. to +70 C/ -40F to 158F.
  • Replacement for: TOCF5 , CPT00072 , 97F5705, Z97F5705 , 97F95702 , Z97F5702 , TT-CAP-5/440 , C305L ,PW-5, TP-CAP-5/440.
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
Check Stock

PowerWell 5 uf MFD 370 or 440 VAC Oval Run Capacitor PW-5 for Fan Motor Blower Condenser in Air Handler Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

  • 5uf / 5MFD 370 Volt or 440 Volt Capacitor. Replaces BOTH 370VAC & 440VAC capacitors.
  • OVAL motor run capacitor. Can size measures 2" Wide , 2.5" Tall and 1.25 " thick. Operating temperature range -40 C. to +70 C/ -40F to 158F.
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • GUARANTEED TO LAST 5 YEARS 100% SATISFACTION GUARANTEE .We are extremely passionate about our products and are fanatical about quality control in our....
  • Replacement for: TOCF5 , CPT00072 , 97F5705, Z97F5705 , 97F95702 , Z97F5702 , TT-CAP-5/440 , C305L , TP-CAP-5/440.
Check Stock

Apex RC Products 12/21 / 27/35 Turn 550 Brushed Electric Motor (21 Turn)

  • WORKS In Most 1/10 Cars & Trucks – Drop In Replacement For Traxxas Brushed Models.
  • LENGTH: 57mm – CAN DIAMETER: 36mm – SCREW HOLES: 26mm SHAFT DIAMETER: 3mm – SHAFT LENGTH: 16mm.
Check Stock

KuangBBBTools 45-5 mfd Round Air Conditioner Capacitor Motor Run Capacitor Withstand Voltage 450V AC Compatible for c3455r GE 97F9895 Z97F995 97F9895BZ3 27L88

  • Professional design for replacement of single or three phase motor capacitors, especicaly for air conditioner or refrigerator.
  • Dural run capacitor 45+5 mfd uf, 450v withstand voltage,50/60 Hz,Polypropylene Metallized Film and vegetable oil filled.
  • 1/4 in.standard Quadruple QCT terminals, 4 terminals per post, for fast repairing and replacment.
  • Built to the toughest standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • Compactible for 97F9895 , Z97F995 , 97F9895BZ3 , 27L880 , TRCD455 , TRCFD455 , PRCFD455 , 27L889 , 97F9851 , 97F9851S , 12788 , RC0114 , Z97F9895 ,....
Check Stock

PowerWell 10 uf MFD 370 or 440 VAC Oval Run Capacitor PW-10 for Fan Motor Blower Condenser in Air Handler Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

  • 10uf / 10MFD 370 Volt or 440 Volt Capacitor. Replaces BOTH 370VAC & 440VAC capacitors.
  • OVAL motor run capacitor. Can size measures 2″ Wide , 3.5″ Tall and 1.25 ” thick. Operating temperature range -40 C. to +70 C/ -40F to 158F.
  • Built to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
  • GUARANTEED TO LAST 5 YEARS. We are extremely passionate about our products and are fanatical about quality control in our workshops. ORDER NOW with peace of mind. No Catches.
  • Replacement for: 97F9002 , 97F9002s , 97F9002BZ3 , Z97F9002 , 27L669 , HC91CA010D , HC91CA010 , HC90AB010 , HC96AC010 , TOCF10 , CR10x370 , TT-CAP-10/440 TP-CAP-10/440 HCKS100V440Z.
Check Stock

10 uF ±5% 10 MFD 370/440V CBB65 Oval Run Start Capacitor Replacement Part by BlueStars - Exact Fit for AC Motor Run or Fan Start and Cool or Heat Pump Air Conditioner - Replaces 27L669 97F9002

  • 10uf / 10MFD 370 Volt or 440 Volt Capacitor. Replaces BOTH 370VAC & 440VAC capacitors.
  • Replacement for: 97F9002 , 97F9002s , 97F9002BZ3 , Z97F9002 , 27L669 , HC91CA010D , HC91CA010 , HC90AB010 , HC96AC010 , TOCF10 , CR10x370 , TT-CAP-10/440 TP-CAP-10/440, HCKS100V440Z.
  • OVAL motor run capacitor. Can size measures 2" Wide , 3.5" Tall and 1.25 " thick.
  • Operating Temperature Range -40 ℃ to +70 ℃/ -104℉ to +158℉.
  • Built to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001.
Check Stock

Traxxas 5270R Complete EZ Start 2 Electric Starting System

  • Glow plug is heated automatically by the EZ Start system, eliminating the need to keep up with a separate glow plug igniter.
  • The voltage to the glow plug is kept constant, regardless of the load placed on the starter by the starter motor.
  • The Cush drive mechanism in the drive unit prevents damage to the gears caused by engine kickback.
  • Smart Start protection circuitry prevents damage to the motor by cutting power if the load on the motor or other electronics exceeds safe limits.
Check Stock