Top K Thermocouple Wire Reviews

High Temperature Ceramic K-Type Thermocouple Terminal Block

  • Unglazed Ceramic Thermocouple Connector Block for High Temperature K-type Thermocouples.
  • Connectors are made from Nickel Plated Brass, Accept AWG 8 (3.3 mm) K-type Thermocouple.
  • Big Terminal Screws for Easy Wiring, Accepts Stranded or Solid Wire.
Check Stock

3D Printer T-K500 m3 x 15mm K Type Thermocouple Sensor K-Type Compatible with Volcano V6 HOTEND Block 500℃ PEI PEEK High Temperature 3D Printing

  • This Thermocouple sensor is 3mm x 15mm cylindrical package with 1 meter long cable compatibility with all ID 3mm cartridge-style heater blocks..
  • Thermocouple Wire with 304SS Braid Over Glass Insulation,Durable, Flexible and Long Lasting.
  • Thermocouple sensor for high temperature printing up to 500C and 450 degree long hours guaranteed.
  • Package: 1piece K type thermocouple (Positive wire: Yellow.
  • Thermocouples are very sensitive, requiring a good amplifier with a cold-compensation reference, if you need an amplifier module, please search the ASIN ID " B08C4Z9PZS ".
Check Stock

K-Type Scientific Digital Thermometer DM6801 with high Temperature thermocouple PK-1000

  • Digital k-type thermometer with one input and extra thermocouple PK-1000.
  • Temperature Range: -58.0 to 1999.0 °F (-50.0 to 1300.0 °C).
  • Resolution: 0.1°F or °C or K Accuracy: 2.2° or 0.75% Data Hold.
  • Comes with k-type thermocouple wire probe that measures up to 1832 degree fahrenheit (1000 degree Celsius).
  • Battery: 9V (included!) Dimensions: 6" x 3" x 1.5" (149 x 71 x 41 mm) Weight: 7 oz (200 g).
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock

K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

Instrukart Dry Block High Temperature Calibrator AI-DBC 650 for Calibration Labs Pharmaceutical divisions Thermal Plants divisions Along with Calibration Certificate

  • Accuracy: ±0.6°C, Bath Stability: ±0.5°C.
  • Measuring Functions: J Type Thermocouple, K Type Thermocouple, T Type Thermocouple, R Type Thermocouple, S Type Thermocouple, N Type Thermocouple, MA, MV, Volts, Ohms, RTD (Pt 100).
  • Temperature Steps: 50°C, 150°C, 300°C, 450°C, 600°C.
  • Switch Test: Continuity check with OPEN / CLOSE indication.
  • Transmitter Supply: 24V DC ± 10% (Loop Powered).
  • Power Supply: 230V AC ± 5% / 50Hz, 500 W for 350UTC.
  • Supply Scope: Instrument, Power Cable, Carrying Case, Test Lead(2 & 3 Wire), Insertion Tube, Insertion Tool,Spare Fuses: 6A x 2nos User Manual, Calibration Certificate.
Check Stock

CESARIAS K-Type Panel Mount Thermocouple Mini Plug Connector, Male and Female, Yellow…

  • Type: K Type Male Female Wire Connector Thermocouple Plug Adapter.
  • High Quality: Yellow plastic shell ensures good insulation, and 2 flat metal male pins construct ensures good contact..
  • Fine workmanship, stable performance, durable in use..
  • Function: Allow you to use the new thermocouples with olter thermometer or some multimeters for contact temperature measurement..
  • Purpose: Be widely used in thermocouple and RTD circuits, best solution for quick and good contact. Can be used with k type digital thermometer to measure temperature of air and gas..
Check Stock

Montague OVEN THERMOCOUPLE 48\ 1036-7

  • K-type thermocouple connector with real chromel alumel contacts.
  • Miniature or mini k-type connector dimensions.
  • Works with all k-type thermocouple wires and extension wires.
  • Set of 10 male mini thermocouple connector plugs.
  • Compatible with thermocouple plugs from other manufacturers.
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

Digital pyrometer F,C pottery ceramic glass kiln Sensor Thermometer Thermocouple

  • Digital Pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Ceramic thermocouple Temperature range: -50°C to 1300°C ( -58°F to 2372°F).
  • Included Pyrometer and 2 type K thermocouple ( One 3" K type thermocouple(-50 to 400°C) and one Kiln K type (-50 to 1300°C)).
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Shipping to USA is 3-6 business days. For more information please go to our website Thermomart.
Check Stock

Cooper-Atkins 93230-K Thermocouple Thermometer (Thermocouple K Type Thermometer) - EconoTemp Combo Pack

  • Thermocouple K Type Thermometer - Includes 32311 thermocouple thermometer, wall bracket, and DuraNeedle probe 50336-K. For foodservice and general purpose temperature monitoring..
  • Accurate Thermocouple Thermometer - Temperature range from -40 to 500 degrees Fahrenheit, precise to +/- 2 degrees Fahrenheit across entire range..
  • DuraNeedle 2 Second Response Time - Includes DuraNeedle 50336-K probe with ultra-fast response time. Features easy to read digital display and 10 minute auto shutoff..
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885..
Check Stock

Fluke 51 II Single Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in celsius, fahrenheit, or kelvin via a type k, type j, type t, or type e thermocouple probe.
  • Includes a type k bead thermocouple probe with a 40" cable that measures from minus 40 to +260 degrees c ( minus 40 to +500 degrees f).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to nist standards for compliance with regulations.
Check Stock

Fluke - FLUKE-52-2 60HZ 52-2 60HZ Dual Input Digital Thermometer

  • Thermocouple thermometer for use in applications requiring a broad range of temperatures, including furnaces, kilns, freezers, and other industrial applications.
  • Measures temperatures in Celsius, Fahrenheit, or Kelvin via a Type K, Type J, Type T, or Type E thermocouple probe.
  • Includes a Type K bead thermocouple probe with a 40" cable that measures from -40 to +260 degrees C (-40 to +500 degrees F).
  • Provides the relative time of minimum, maximum, and average temperature measurements for monitoring.
  • Conforms to NIST standards for compliance with regulations.
Check Stock