Top 3tf Contactors Reviews

Electrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws

  • BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
  • one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
  • CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check Stock

Goodman - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A

  • n accordance with U.L. Bulletin No. 508 "Industrial Control Equipment", contactors meet specifications for devices up to 600 VAC..
  • Includes Lug, spade terminals, and covers..
Check Stock

Surge Guard 40100 Basic Automatic Transfer Switch - 50 Amp

  • Time delay at power up. Connection type: Screw terminals.
Check Stock

Cabin Air Filter Replacement FL3Z19N619A with Nutshell Activated Carbon Compatible with FORD EXPEDITION/F-150/F-250/F-350/F-450/F-550SUPER DUTY LINCOLN NAVIGATOR 2018-2020.

  • Cabin Air Filter Material:Melt blown electrostatic layer+ HEPA Filter layer+ Nutshell activated carbon..
  • Comfortable Car Environment:Cabin Air Filters prevent harmful fine particles and dust from entering the vehicle cabin while keeping a clean and....
  • Design:With a high-density electrostatic electret filter and special Honeycomb Design, they had nutshell activated carbon inside so the maximized....
  • Compatible With Models:FORD EXPEDITION(2018-2020),F-150(2015-2020),F-250/F-350/F-450/F-550 SUPER DUTY(2018-2020).
  • Alternate/OEM Part Number(s):DR3Z19N619A,FP72,E3TF11000AA,FP79,JL7Z19N619A,FL3Z19N619A.
Check Stock

NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)

  • 10.0 - 16.0 Amp, IEC, Overload Relay, Type: Thermal Bi-Metallic. Trip Class 10. Selectable Manual or Automatic Reset. For use with XT Series, Frame D Contactors..
Check Stock

Packard - DP301202 C230B 2 Pole 30 Amp Contactor, 120 Voltage Coil

  • Compatible with: C230B/ TJT30A120V2P/17325/PC230A/H230A/90-244.
  • In accordance with U. L. bulletin no. 508 “industrial control equipment”.
  • Contactors meet specifications for devices up to 600 VAC.
  • Coils have class b insulation. Resistive Amps : 40.
  • Includes lug, spade terminals, and covers.
Check Stock

20 in. x 20 in. x 1 in. Basic Household Pleated Air Filter (3-Pack)

  • This is a Brand New Upgraded 1 Pole 30 Amp Condenser Contactor.
  • This contactor is rated for 30 amps, meaning it is an upgrade for old 25 amp contactors.
  • The coil is rated for 24 volts- It also has a sealed contact!.
  • This contactor will work with 99% of residential units!.
Check Stock

Lennox - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A

  • 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
  • Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
  • Base assembly is made from high performance Bulk (Dough) molding compounds.
Check Stock

115/230VAC Pulling Electric Winch with 11.0 fpm and 2000 lb. 1st Layer Load Capacity

  • All brass (no corrosion) series wound that is double sealed.
  • Sealed waterproof 600 amp contactors and steel contactor cover for added protection.
  • Double sealed drum (gearbox/motor) and sealed 3 stage planetary gears as well as aluminum fairleads and integrated wireless remote.
  • Fully sealed to Ip68 standard and tie bars reinforced with steel body.
Check Stock

Trane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A

  • 200K cycles UL testing approval for Dp contactor.
  • Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
  • UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
  • Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check Stock

NEW TeSys LRD thermal overload relays LR-D16 LRD16 9-13A Class 10A

  • Class 10 Ambient Compensated Overload with Phase Loss Protection..
  • New Aftermarket Replacement for Telemecanique Overload Relay including a 1 year warranty..
  • "12-18A Adjustable Overload Mounts to NC1- D12, D18, D25 or D32 Contactor".
  • Series LR overload relays are intended and UL recognized for use with US Breaker NC1D contactors..
  • Telemecanique parts are provided to assist selection. Select products according to each applicaion..
Check Stock

MGN9H Carriage Block for MGN9 Linear Sliding Rail Guide

  • Multipurpose : Can be installed in all types of terminal boxes, distribution boxes, control cabinets, switchgear, complete sets of equipment, machinery and equipment..
  • Versatility : Perfect for any type of electronic component or device, such as relays, contactors, breakers and more.
  • Easy to install : Practical design with screws for easy installation.
  • Length : 100mm/ 4"(-1%) (For easy installation).
  • Package Contents: 3pcs x DIN rails + 6pcs x screws.
Check Stock

Mcdonnell & Miller Flow Switch, 1 in SPDT FS4-3

  • Working Temperature: -10 to 50 Degrees Celsius.
  • Tip: The max switching current of the contact is 0.5A. Generally, it should be used together with small relay. Excessive current will burn the contact. Cannot directly control AC contactors, solenoid valves, alarms, pumps, and various lights..
  • What is in the package: 2pcs M16 Water Level Sensor.
Check Stock