Top 3 phase Ac Ssr Reviews

SSR-100DD Solid State Relay DC to DC (Input 3-32V DC Output 5-60V DC) with Heat Sink, 100A

  • Model: SSR-100DD, single phase Solid State Relay 100A DC to DC control, CE Compliant to EN60950-1.
  • Input voltage 3-32V DC, Load voltage 5-60V DC, Max load current 100 Amp.
  • Rugged epoxy encapsulation construction, high isolation over than 50MΩ(500VDC), high dielectric over than 2.5KV, output snubber circuit protection.
  • No EMI/EFI & Low surge by Zero Cross Trigger method, specially suited to control sensitive, capacitive and Non-saturated inductive loads.
  • SSR switches use semiconductor component acts as a switch for the relay, no moving parts inside, no mechanical wear, no action noise, no mechanical failure, and high reliability.
Check Stock

SSR-25DD Solid State Relay DC to DC (Input 3-32V DC Output 5-60V DC) with Heat Sink, 25A

  • Model: SSR-25DD, single phase Solid State Relay 25A DC to DC control, UL Approved, CE Compliant to EN60950-1.
  • Input voltage 3-32V DC, Load voltage 5-60V DC, Max load current 25 Amp.
  • Rugged epoxy encapsulation construction, high isolation over than 50MΩ(500VDC), high dielectric over than 2.5KV, output snubber circuit protection.
  • No EMI/EFI & Low surge by Zero Cross Trigger method, specially suited to control sensitive, capacitive and Non-saturated inductive loads.
  • SSR switches use semiconductor component acts as a switch for the relay, no moving parts inside, no mechanical wear, no action noise, no mechanical failure, and high reliability.
Check Stock

PRINCE CASTLE Drive Motor Assembly 87-028AS

  • ATO 110v vfd, single phase 110v/120v input, single phase or three phase 220v output, achieve to run 220v AC motor on single phase 110v/120v power supply.
  • 【Voltage& Frequency】Input voltage: 1 phase 120V AC ±15%, Input frequency: 50Hz/60Hz,Output voltage: 1 phase or 3 phase 220V AC ±15%, Output frequency: 0.00~400.00Hz.
  • 【APPLICATION】ATO 7.5 hp 5.5kW variable frequency drive Can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc.
  • 【TIPS】 To protect the variable frequency drive and Motor, you need an upstream protection, add a line-choke upstream the VFD, this will reduce the current transients seen by the input of the VFD.
  • 【CUSTOMER FIRST】If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD.If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
Check Stock

ATO 1 hp VFD, 4A 0.75kW 120V Input 220V Output, Single Phase to 1phase/3phase Variable Frequency Drive, for AC Motor Speed Control

  • ATO 1 hp 110v VFD, 0.75 kW single phase 110v/120v input, single phase or three phase 220v output variable frequency drive. Running your 1 phase/3 phase motors on 120 volt supply via ATO VFD.
  • Input voltage: 1 phase 120V AC ±15%, Input frequency: 50Hz/60Hz, Output voltage: 1 phase or 3 phase 220V AC ±15%, Output frequency: 0.00~400.00Hz.
  • 【APPLICATION】: ATO 110V Variable frequency drive can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc..
  • 【TIPS】: Choose a VFD base on motor rated current: VFD output current ≥ motor rated current.
  • 【CUSTOMER FIRST】If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
Check Stock

Nema34 8N.m Closed Loop Stepper Servo Motor 116mm 6A 2 Phase+HSS86 Hybrid Servo Motor Driver Controller 70V/AC 100V/DC CNC Kit for CNC Router Engraving Milling Machine

  • ATO 2 hp (1.5 kW) VFD, single phase 110V/120V input, 1 phase or 3 phase 220v-240v output, designed for driving single/three phase AC motor via 120v power supply.
  • 【Voltage&Frequency】Input voltage: 1 phase 120V AC ±15%.
  • Output voltage: 1 phase or 3 phase 220V AC ±15%.
  • 【APPLICATION】 ATO 110V VFD Can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc..
  • 【TIPS】 Choose a VFD base on motor rated current: VFD output current ≥ motor rated current.
  • 【CUSTOMER FIRST】 If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD.If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
Check Stock

ATO 3 hp 2.2kW 10A VFD, Single Phase 120V Input, 1phase/3phase 220V Output Variable Frequency Drive Motor Control

  • ATO 3 hp (2.2 kW) VFD, single phase 110v/120v input, single phase or three phase 220v output variable frequency drive, specially designed for 120v power supply.
  • 【voltage&frequency】Input voltage : 1 phase 120V AC ±15%.
  • Output voltage: 1 phase or 3 phase 220V AC ±15%.
  • 【APPLICATION】: ATO 110V VFD Can be widely applied to drive the AC motor, such as fans, pumps, power tools, etc..
  • 【TIPS】: Choose a VFD base on motor rated current: VFD output current ≥ motor rated current.
  • 【CUSTOMER FIRST】: If you have no experience in driving a VFD, be sure to refer to the instructions before operating a VFD.If you are not sure about the size or have any issue about the product or service, please don't hesitate to email us. We will answer you within 12h.
Check Stock

MYPIN® Universal Digital TA6-SNR PID Temperature Controller with Relay DIN 1/8 SSR-25DA and K type thermocouple,Dual Display for F/C,7 Output Combinations,Accuracy 0.2%

  • √ ● Dual display for Fahrenheit(F) and Celsius(C),Range: -1999 to 9999 (depends on the input signal).
  • √ ● Input: Thermo Resistor: PT100, Cu50,Thermocouple: K,Wre3 ~ Wre25 , Main Output: SSR: Open circuit: 4V, Closed Circuit: 24V 40mA DC.
  • √ ● K type thermocouple Temperature rang:0-800℃, Sensor Dia: 4.5mm, Cable Length: 2m.
  • √ ● Solid state relay SSR-25DA Load Voltage: AC 24-380V, Load Current: 25A, Input Voltage: DC 3-32V.
  • √ ● Packing details: 1 x SNR Temperature Controller( DIN 1/8), 1 x SSR-25DA Solid State Relay, 1 x K Type Thermocouple( 6 Feet).
Check Stock

TWTADE SSR-40VA 500K ohm 1/4W to 24-380VAC 40A Single Phase Solid State Relay Resistance Voltage Regulator Authorized+Heat Sink+Potentiometer+A knob

  • Specifications: This is solid state relay SSR-40VA..
  • Input Resistance/Power: 500Kohm/2W Output voltage: 24-380V AC.
  • Heat Sink Mounting Thread Diameter (Approx.) : 0.5cm / 0.19".
  • Heat Sink Total Size (Approx.) : 8 x 4.9 x 4.9cm / 3.1" x 1.9" x 1.9" (L * W * T ).
  • Package Content: 1 x SSR, 1 x heat sink, 1 x 470Kohm potentiometer ,1 x knob.
Check Stock

6PCS SSR-40DA Solid State Relay Single Phase Semi-Conductor Relay Input 3-32V DC Output 24-380V AC

  • Product name: solid state module relay SSR-40DA, 3-32VDC/24-380VAC..
  • SSR Application: with a switch no spark, no noise,high switching speed,anti-corrosion,moisture-proof,anti-vibration,long life.high reliability,electromagnetic compatibility and other characteristics..
  • Solid state relay ideal for automatic process control application, a must component for temperature controller and other machinery control system..
  • Especially suitable for corrosion, moisture, dust, and other harsh environments, and frequent switching the occasion, AC contactor is updated alternative..
  • High reliabily, compact size, a great part for temperature controller and other machinery control system..
Check Stock

Extech PQ2071 True RMS 1/3 Phase 1000A AC Power Clamp Meter

  • Meter operates as a True RMS Clamp Meter, Power Meter, Multimeter, and AC Voltage Detector.
  • Measures AC Current, Voltage, Frequency and Power including True Power, Apparent Power, Reactive Power and Active Power.
  • Measures 1-Phase/ balanced 3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR) and Active Power (kWh),plus Power Factor/ Phase Angle.
  • Large dual backlit LCD display (9999 count) with bargraph.
Check Stock

MYSWEETY 3PCS SSR-40DA Solid State Relay Single Phase Semi-Conductor Relay Input 3-32V DC Output 24-380V AC

  • Product name: solid state module relay SSR-40DA, 3-32VDC/24-380VAC..
  • SSR Application: with a switch no spark, no noise,high switching speed,anti-corrosion,moisture-proof,anti-vibration,long life.high reliability,electromagnetic compatibility and other characteristics..
  • Solid state relay ideal for automatic process control application, a must component for temperature controller and other machinery control system..
  • Especially suitable for corrosion, moisture, dust, and other harsh environments, and frequent switching the occasion, AC contactor is updated alternative..
  • High reliabily, compact size, a great part for temperature controller and other machinery control system..
Check Stock

CNAODUN PID Temperature Controller Kit 100-240 VAC Voltage with 40DA Solid State Relay,K Type Thermocouple Probe and Heat Sink

  • ♥【One Way SSR output】3,4 port output to SSR,a 40da solid state relay is included in the package.The power supply voltage for this Pid temperature controller is 100-240VAC..
  • ♥【One Alarm Output】6,7 ports are alarm outputs, AC220V/DC30V 3A (Resistive load) ON/NC, also can be used to connect relay..
  • ♥【Supports 2 Wire Sensor Input】Support two-wire thermocouple input, K, E, J, N, W3-25, W5-26 type thermocouple input are available, the default setting is K type thermocouple input.
  • ♥【℉ and ℃ Adjustable】Fahrenheit and Celsius adjustable, default is Fahrenheit, with PID function.
  • ♥【Temperature Digital Display】PV is the current measured temperature, SV is the set temperature, both are displayed simultaneously..
Check Stock

Omron K8DS-PH1 Phase Monitoring Relay

  • The base of the protector adopts a rail type with two screw holes, which can be directly installed separately or mounted on the HT35 rail..
  • Use 5 indicators to indicate: normal, phase loss (voltage three-phase unbalance), reverse phase, overvoltage and undervoltage..
  • Phase loss protection means that when the protected line is in the running state or non-operating state, any phase failure occurs, and the delay is 2S..
  • Overvoltage protection means that the voltage of the protected line is higher than the set value, and the delay is 3~8S, and the recovery is 6~20VAC..
  • Reverse phase protection, a protection measure to prevent L1, L2, L3 three-phase AC phase sequence from being connected incorrectly, delay 2S action..
Check Stock